INSTALLATION
MANUAL
Cross Platform Control
Specifications, Installation and Programming
M1 includes the SIA CP-01 Standards for False Alarm Reduction
TM
L520 Rev. J 11/11/10 Current with Firmware 5.2.x
Przeglądanie stron 0
1 2 3 4 5 6 ... 71 72

Podsumowanie treści

Strona 1 - INSTALLATION

INSTALLATIONMANUALCross Platform ControlSpecifications, Installation and ProgrammingM1 includes the SIA CP-01 Standards for False Alarm Reduction †TML

Strona 2 - Introduction

M1G Installation and ProgrammingPage 10Two-Wire Smoke Zones (Zone 16)To enable use of two-wire smoke detectors on Zone 16, position Jumper JP1 (locate

Strona 3 - Table of Contents

M1G Installation and ProgrammingPage 11AC Failure, Low Battery, and Automatic Low Voltage ShutdownDuring an AC power failure the battery automatically

Strona 4 - Cross Platform Control

M1G Installation and ProgrammingPage 12Data Bus E.O.L. Termination - VERY IMPORTANT!The M1 data bus comforms to EIA RS-485 standards and operates at 3

Strona 5 - † Supported 16

M1G Installation and ProgrammingPage 13Setting the Data Bus Address and Enrolling Device(s) into the SystemKeypads and Expanders communicate over the

Strona 6 - Wiring & Hookup Diagram

M1G Installation and ProgrammingPage 142.1 IntroductionThe control has factory default programming which make it easy to bench test prior to installat

Strona 7

M1G Installation and ProgrammingPage 15Ready Light - ON when all burglar zones are secure and the system is OK to arm. If OFF, one or more zones are

Strona 8 - 1.1 Planning the Installation

M1G Installation and ProgrammingPage 16Access to menus 1 to 5 can be restricted via programming to only Users that have “User Code Option 8” set. Men

Strona 9 - 1.4 Control Wiring

M1G Installation and ProgrammingPage 173-Walk Test Area r < Area? Name >4-View History rLog6-Change rUser CodesRequires Master orInstaller Code

Strona 10 - Standby Battery Connection

M1G Installation and ProgrammingPage 18To perform system tests press the right arrow key. Then press the up or down arrow keys toselect one of the thr

Strona 11 - Earth Grounding

M1G Installation and ProgrammingPage 199-Installation rProgramming (0)87-CustomMessage Record r† This option is used in conjuction with a house telep

Strona 12 - Terminate

M1G Installation and ProgrammingPage 2IntroductionLIMITATIONThe ELK-M1G Control is designed to warn against unauthorized entry and other situations. H

Strona 13 - KeypadKeypad

M1G Installation and ProgrammingPage 20Menu 0 - Select Keypad Alternate Area - Multi-area (Partition) OperationPress the RIGHT arrow key to select th

Strona 14 - 2.2 Powering Up (One Keypad)

M1G Installation and ProgrammingPage 213.1 IntroductionThe Security functionality of the M1 Control can be programmed either from an ELK-M1KP LCD Keyp

Strona 15 - 2.5 Keypad Overview

M1G Installation and ProgrammingPage 223.5 Communicator Setup ChecklistThe Communicator (Dialer) can dial up to 8 phone numbers plus RP. Digital repo

Strona 16 - Keypad Menus

M1G Installation and ProgrammingPage 23ELK-M1G QUICK REFERENCE - MENU PROGRAMMINGMenu 01 Menu 04 Menu 06 Menu 07 Menu 08 Menu 10 Menu 13Bus Mod Enrol

Strona 17

M1G Installation and ProgrammingPage 24Menu 01 - Bus Module Enrollment01-Bus ModuleEnrollment rBus Module Enroll Description of OptionEnrollingBus Mod

Strona 18

M1G Installation and ProgrammingPage 25001 09:=No rDuress001: Selb PrgrUser 1001 01:12345678 rCode used inArea001 02:=Yes rArm with Code001 03:=Yes rD

Strona 19 - Installer

M1G Installation and ProgrammingPage 26A1: Selb PrgrArea 1A1 01:=060 rExit Delay1 TimeA1 02:=030 rEntry Delay1TimeA1 03:=060 rExit Delay2 TimeA1 04:=0

Strona 20

M1G Installation and ProgrammingPage 27A1 11:=No rStayInstantScrA1 12:=Yes rNight ScrollA1 13:=No rNightInstantScrA1 14:=No rStayChgIfArmedIf Yes, a C

Strona 21 - 3.4 Area Partitioning

M1G Installation and ProgrammingPage 28KP01 03:=No rSilent on ExitKP01 04:=No rSilent on ChimeKP01 05:=No rGo dark in 60secKP01 06:=Yes rShow Date &am

Strona 22 - Enter Valid Pin

M1G Installation and ProgrammingPage 29Menu 04 - Keypad Definitions (continued)Keypad Definitions Description of OptionKP01 10:F1 Key rDefinitionsF1K

Strona 23

M1G Installation and ProgrammingPage 3Table of ContentsSpecifications, Features, and Benefits ...

Strona 24

M1G Installation and ProgrammingPage 30ZN001: Selb PrgrZone 001ZN001 01:Def=01 rBurg Entry/Exit1Menu 05 - Zone Definitions05-Zone rDefinitionsZone Def

Strona 25 - Menu 02 - User Code Options

M1G Installation and ProgrammingPage 31ZN001 02:Type=0r0=EOL SupervisedZN001 03:Area=1 r[Area Name]Refers to the wiring configuration for zones. Bur

Strona 26 - Menu 03 - Area Definitions

M1G Installation and ProgrammingPage 32ZN001 13: =No rIn CrossZonePoolMenu 05 - Zone Definitions (continued)Zone Definitions Description of OptionA zo

Strona 27

M1G Installation and ProgrammingPage 33CT01:=00600 secrBurgDurationCT02:=00000 secrFireDurationMenu 06 - Alarm Duration Timers06-Alarm Cutoff rTimersA

Strona 28 - Menu 04 - Keypad Definitions

M1G Installation and ProgrammingPage 34G01:=0 TelRmtCtlIn&OutsidTeleCtlG02: =Yes r12Hr Time DispG03: =No rDD/MM Date DispMenu 07 - Global System D

Strona 29

M1G Installation and ProgrammingPage 35G14: =No Out1&2rChg YelpToBuzzerG15:=1 Out1StartrAlarm Volum-TstrG16:=7 Out1 MaxrSiren Volum-TstrG17: =5 O

Strona 30 - Menu 05 - Zone Definitions

M1G Installation and ProgrammingPage 36Menu 07 - Global System Definitions (continued)Global Sys Definitions Description of OptionAllows Output 2 to b

Strona 31 - [Area Name]

M1G Installation and ProgrammingPage 37Menu 07 - Global System Definitions (continued)† This option sets the control to transmit automation task stat

Strona 32

M1G Installation and ProgrammingPage 38T1: Selb Prgr[Name for Tel#1]T1: 02: = 0 r0=Always ReportMenu 08 - Telephone Account Setup08-Telephone rAccount

Strona 33

M1G Installation and ProgrammingPage 39T1: 12:=000000rAcct # for Area8T1: 13:=Yes RptrAreaAlms,RestUnbpT1: 14:=No RptrBypassesTelephone Acct Setup Des

Strona 34 - NOTE: The Cross Zone

M1G Installation and ProgrammingPage 4OUT3 On LEDJ-16 Programmable Outputs See Note 1& Note 2PLC ††LightingInterfaceCo

Strona 35

M1G Installation and ProgrammingPage 40AR1: Selb PrgrReportCodesArea1AR1 01:000=Sec rDialer Delay TimeAR1 02:Code= 00rAlm Abort CodeMenu 09 - Area Rep

Strona 36

M1G Installation and ProgrammingPage 41Area Report Codes Description of OptionDuress code will be reported if the area is armed or disarmed by a valid

Strona 37 - † Not evaluated by UL

M1G Installation and ProgrammingPage 42Z001: Selb Prgr[Name of Zone]Z001:A=00 R=00 rByp=00 Tbl=00Menu 10 - Zone Reporting Codes10-Zone ReportngCodes

Strona 38

M1G Installation and ProgrammingPage 43Menu 11 - Keypad F-Key Reporting Codes11-Keypad F-KeyrReporting CodesPress RIGHT arrow key to select this menu.

Strona 39

M1G Installation and ProgrammingPage 44SR01: 015=AC FailRpt Delay - MinrSR02: T=00 R=00 rAC Fail CodesSR03: 00 = AutorTest CodeMenu 12 - Sys Report Co

Strona 40

M1G Installation and ProgrammingPage 45SR14: T=00 R=00 rPhone Line FaultSR15: T=00 R=00 rOutput 2 TroubleSR13: 00= Up/ rDownload EndLog 80% Full repor

Strona 41

M1G Installation and ProgrammingPage 46UR001: Selb Prgr[Name of User]UR001:O=00 C=00r[Name of User]Menu 13 - User Report Codes13-User ReportCodes rUse

Strona 42

M1G Installation and ProgrammingPage 47Menu 14 - Wireless DefinitionsWirelessDefinitions DescriptionWireless Definitions menu is broken into four sect

Strona 43

M1G Installation and ProgrammingPage 48WZnxxx:Selr PrgrWireless ZoneWZnxxx 01:=No rEnable TransmitrWZnxxx02:=0 rSupervision TypeWZnxxx

Strona 44

M1G Installation and ProgrammingPage 494.1 ELK-RP SoftwareELK-RP (RP) is a Windows based software package that is compatible with Windows 98and later

Strona 45

M1G Installation and ProgrammingPage 5General:• Large zone capacity: 16 on-board zones expandable to 208• Wireless capability † Up to 144 zones• Two W

Strona 46 - Menu 13 - User Report Codes

M1G Installation and ProgrammingPage 504.1.2 Check for ConflictsDuring the connect and disconnect process RP performs an automatic check of the data s

Strona 47 - SWITCHES TO OFF!

M1G Installation and ProgrammingPage 514.3 Automation Rules and AttributesThe RP Automation Programming software offers powerful, easy to setup and m

Strona 48

M1G Installation and ProgrammingPage 52† LIGHTING - The control can handle up to 256 Light (or appliance) devices. Each is assigned to one of 256

Strona 49 - 4.1 ELK-RP Software

M1G Installation and ProgrammingPage 53† VOICE - This section is used to setup and customize many of the 6 word phrases that can be spoken by the c

Strona 50 - 4.1.2 Check for Conflicts

M1G Installation and ProgrammingPage 54† THERMOSTATS - HVAC Thermostats may be read and/or controlled by the control and its automation rules engin

Strona 51

M1G Installation and ProgrammingPage 55RULES - This section essentially brings all the power of the control’s automation and its features together.

Strona 52 - † LIGHTING

M1G Installation and ProgrammingPage 56AND - The second and optional element of a rule is a qualifier. Rules can have one or more qualifiers OR none

Strona 53 - † VOICE

M1G Installation and ProgrammingPage 57Examples of Rules - Shown below are a series of rules that should help illustrate the power and results that r

Strona 54 - † THERMOSTATS

M1G Installation and ProgrammingPage 580000 = No Event N0001 = Burg Entry/Exit 10002 = Burg Entry/Exit 20003 = Burg Perimeter Instant0004 = Burglar In

Strona 55

M1G Installation and ProgrammingPage 59“Reset” AttributeThe letter(s) displayed in Reset column indicate what condition(s) it takes toclear an event o

Strona 56

M1G Installation and ProgrammingPage 6+SAUXNEG+VAUXNEG+VAUXNEG+VAUXNEGACNORMALZONE 16JP1SW116.5 VJUMPER TO STARTWITH NO ACPOWERTELCO SEIZEDACZ9NEGZ10Z

Strona 57

M1G Installation and ProgrammingPage 60Appendix B - Telephone Remote ControlThere are two methods of entry:Operation from an Inside Telephone:1. Lift

Strona 58 - Appendix A - Event Codes

M1G Installation and ProgrammingPage 61 Automation Menu continuedFor Keypad Temperature - press 5. Certain models of keypads have a built-in temperat

Strona 59

M1G Installation and ProgrammingPage 62{Blank} = 0Zero = 21One = 22Two = 23Three = 24Four = 25Five = 26Six = 27Seven = 28Eight = 29Nine = 30Ten = 31El

Strona 60

M1G Installation and ProgrammingPage 63Location = 267Lock = 268Low = 269Lower = 270MM = 271Machine = 272Mail = 273Main = 274Mains = 275Manual = 276Mas

Strona 61

M1G Installation and ProgrammingPage 64Using a Two Way Interface board (ELK-M1TWI), the control can accommodate up to 3 zones of listen-in. Each zone

Strona 62 - *RP only *

M1G Installation and ProgrammingPage 65This control has been self-verified to be compliant with the SIA CP-01 Control Panel Standard - Features for Fa

Strona 63 - (cont.)

M1G Installation and ProgrammingPage 66Appendix F - Regulatory Agency StatementsFCC: This control complies with Part 68 of the FCC rules. On the fro

Strona 64 - Dialer Activated (Alarm)

M1G Installation and ProgrammingPage 67Home Health Care (UL 1637) Listed InstallationsRequirements described under UL985 plus:* A minimum of two (2) k

Strona 65

M1G Installation and ProgrammingPage 68† Not evaluated by ULNOTE: A recent revision to UL985 requires that a minimum 1/4” separation be provided and

Strona 66

M1G Installation and ProgrammingPage 69M1KP KEYPAD ON-BOARD TEMPERATURE SENSOR †The ELK-M1KP Keypad has an on-board temperature sensor. (NOTE: The E

Strona 67 - Keypads, Expanders

M1G Installation and ProgrammingPage 7(Right Side Terminals)OUT1+12V (+VAUX)NEG16151413121110987NEG -DATA B+12VDATA BUS-ABCJ3 J41 WAYPLCMode2 WAYJP2R

Strona 68

M1G Installation and ProgrammingPage 70M1 LIMITED WARRANTYThe ELK-M1 and its associated component products are warranted by Elk Products, Inc. (“Manuf

Strona 69 - OPTIONAL PROX CARD READER †

M1G Installation and ProgrammingPage 71IndexAAlarm Abort 40Alarm Cutoff Timers 33Anti-Takeover 21Area Partitioning 21Area Reporting Codes 40, 41A

Strona 70

www.elkproducts.comPrinted in USA

Strona 71

M1G Installation and ProgrammingPage 81.1 Planning the InstallationThe first step in any multi-zone security system installation is planning the job.1

Strona 72 - Printed in USA

M1G Installation and ProgrammingPage 91.4 Control WiringZone Inputs (1 thru 16 on main board, 17 thru 208 via expanders)Zones are arranged in groups o

Komentarze do niniejszej Instrukcji

Brak uwag